English
Language : 

E2666B Datasheet, PDF (8/26 Pages) Keysight Technologies – X-Series Oscilloscopes
08 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet
Specifications/Characteristics
I2C specifications/characteristics (DSOX2EMBD, DSOX3EMBD, and DSOX4EMBD
Clock and data input source
Analog channels 1, 2, 3, or 4
Digital channels D0 to D15 (3000, 4000 and 6000 X-Series only)
Max clock/data rate
Up to 3.4 Mbps
Triggering
Start condition
Stop condition
Missing acknowledge
Address with no acknowledge
Restart
EEPROM data read
Frame (Start:Addr7:Read:Ack:Data)
Frame (Start:Addr7:Write:Ack:Data)
Frame (Start:Addr7:Read:Ack:Data:Ack:Data2)
Frame (Start:Addr7:Write:Ack:Data:Ack:Data2)
10-bit write
Hardware-based decode
Data (HEX digits in white)
Address decode size: 7 bits (excludes R/W bit) or 8 bits (includes R/W bit)
Read address (HEX digits followed by “R” in yellow)
Write address (HEX digits followed by “W” in light-blue)
Restart addresses (“S” in green, followed by HEX digits, followed by “R” or “W”)
Acknowledges (suffixes “A” or “~A” in the same color as the data or address preceding it)
Idle bus (mid-level bus trace in dark blue)
Active bus (bi-level bus trace in dark blue)
Unknown/error bus (bi-level bus trace in red)
Multi-bus analysis
I2C plus one other serial bus, including another I2C bus. (3000, 4000 and 6000 X-Series only)