4000 Datasheet, PDF (5/37 Pages) C&D Technologies – Toroidal Surface Mount Inductors
05 | Keysight | InfiniiVision 4000 X-Series Oscilloscopes - Data Sheet
Oscilloscope Experience Redefined:
Experience the Speed (Continued)
Keysight achieves this industry-leading waveform update rate with
MegaZoom IV smart memory technology
Traditionally, CPU processing was the major bottleneck for oscilloscope waveform
update rate and responsiveness. Typically, the CPU handles interpolations, logic channel
plotting, serial bus decoding, measurements and more, and the waveform update rate
drops dramatically as these features are turned on.
The InfiniiVision 4000 X-Series requires minimum support from a CPU, as most core
operations are handled by Keysight proprietary technology, the MegaZoom IV smart
memory ASIC. MegaZoom includes hardware serial decoders and hardware mask/
limit testing capability, plots analog and digital data directly to the display, supports
GUI operation, and integrates additional instruments like the dual-channel WaveGen
function/arbitrary waveform generator.
Analog
signals
16 digital
signals
MegaZoom IV ASIC
Acquisition
memory manager
(Segmented memory)
DRAM
(Acquisition memory)
Serial
decoders
Trigger
(InfiniiScan and
traditional)
Plotter
DRAM
GUI
Mask
WaveGen
Synthesis
Handware
accelerated
(Measurements, Search)
CPU
(Math, I/O, GUI)
Figure 6. The 4000 X-Series oscilloscopes’ uncompromised responsiveness, speed and waveform update rate is enabled by the MegaZoom IV, smart
memory ASIC. The CPU is not used for core waveform operations.