English
Language : 

4000 Datasheet, PDF (25/37 Pages) C&D Technologies – Toroidal Surface Mount Inductors
25 | Keysight | InfiniiVision 4000 X-Series Oscilloscopes - Data Sheet
Oscilloscope Experience Redefined:
InfiniiVision 4000 X-Series Performance Characteristics (Continued)
Horizontal system analog channels
Time base range
Time base accuracy 1
Time base delay time range
Channel-to-channel deskew range
Δ Time accuracy (using cursors)
Modes
XY
Pre-trigger
Post-trigger
Horizontal system digital channels
Minimum detectable pulse width
Channel-to-channel skew
Acquisition system
Maximum analog channels sample rate
Analog channels equivalent sample rate
Maximum analog channels record length
Maximum digital channels sample rate
Maximum digital channels record length
Modes
Normal
Peak detect
Averaging
High
resolution
Segmented
Roll
Equivalent
time
4022A 4024A 4032A 4034A 4052A 4054A
2 ns/div to 50 s/div
1 ns/div to 50 s/div
± 10 ppm
Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
1 to 500 s
± 100 ns
± 0.001% of reading ± 0.16% screen width ± 30pS
Main, zoom, roll, XY
On channels 1 and 2 only. Z Blanking on Ext Trigger Input, 1.4 V threshold
Bandwidth: Maximum bandwidth. Phase error at 1 MHz: < 0.5 degree
Time base: 200 ns/div to 50 ms/div
4104A 4154A
500 ps/div to 50 s/div
2 ns
2 ns (typical); 3 ns (maximum)
4022A 4024A 4032A 4034A 4052A 4054A 4104A 4154A
5 GSa/s half channel interleaved, 2.5 GSa/s all channels
N/A
128 Gsa/s
4 Mpts half channel interleaved, 2 Mpts all channel
1.25 GSa/s
2 Mpts (with digital channels only)
Default mode
Capture glitches as narrow as 200 ps at all time base settings
Selectable from 2, 4, 8, 16, 64, ... to 65,536
Real-time boxcar averaging reduces random noise and effectively increases vertical resolution
–– 12 bits: ≥ 50 μs/div
–– 11 bits: ≥ 20 μs/div
–– 10 bits: ≥ 10 us/div
–– 9 bits: ≥ 5 us/div
Segmented memory optimizes available memory for data streams that have long dead times
between activity. Maximum segments = 1000. Re-arm time = 1 μs (minimum time between trigger
events). Re-arm time when used with the InfiniiScan Zone = 65 us or faster (typical)
Displays the waveform moving across the screen from right to left. Available at the time base
50 ms/div or slower
1 GHz and 1.5 GHz models only. 7.8 ps fine interpolator resolution yields a maximum effective
sample rate of 128 GSa/s
1.  Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ± 10 °C from firmware calibration
temperature.