28 | Keysight | Power Products – October 2015 - Selection Guide
B1505A Power Device Analyzer / Curve Tracer
The B1505A Power Device Analyzer /
Curve Tracer is a single box solu-
tion for power device evaluation. Its
broad measurement range from sub-
pA to 10 kV/1500 A enables precise
µΩ on-resistance measurements.
Additionally, its 10 µs fast pulse
capability enables complete power
device characterization. This allows
evaluation of new power devices
such as IGBT and wide band-gap
materials such as silicon carbide
(SiC) and gallium nitride (GaN).
– Very wide current, voltage oper-
ating range up to 1500 A,10 kV
– Supporting package and on-wa-
fer device
– Accurate sub-picoamp level
current measurement and μΩ
on-resistance measurement
– 10 μs high power narrow pulse
measurement
– Three-terminal capacitance
(Ciss, Coss, Crss) measurement
at up to 3000 V DC bias volt-
ages and independent terminal
capacitance (Cgs, Cgd, Cds)
measurement
– Gate charge (Qg) measurement
– GaN current collapse measure-
ment
– Automated thermal test from
-50 ˚C to +250 ˚C
– Upgradable and scalable hard-
ware architecture
– Oscilloscope View for current
and voltage pulse veriication
– EasyEXPERT software simpliies
data management and data
analysis
B1505A Modules
B1510A
B1511B
B1512A
B1513C
B1514A
B1520A
External Modules
N1265A
N1266A
N1267A
N1268A
Accessories
N1258A
N1259A
N1260A
N1271A
N1272A
N1273A
N1274A
N1275A
Description
High power SMU
Medium power SMU
High current SMU
High voltage SMU
Medium current SMU
Multi-Frequency CMU
Description
Ultra high current ex-
pander / Fixture
HVSMU Current Ex-
pander
High voltage/high cur-
rent fast switch
Ultra High Voltage Unit
Key speciication
200V, 1 A (DC),
10 fA resolution
100 V, 100 mA (DC),
10 fA resolution
20 V, 20 A (Pulsed)
30 V, 1 A (DC)
3000 V, 8 mA
(Pulse and DC)
30 V, 1 A (Pulsed)
30 V, 100 mA (DC)
1 kHz to 5 MHz, ±25 V
(internal bias)
Key speciication
Max Number
4
10
2
5
5
1
±1500 A / 60 V (Pulsed)
±1500 V/2.5 A (Pulsed),
±2200 V/1.1 A (Pulsed)
±3000 V, ±20 A (Pulsed),
Minimum transition (OFF to ON) : 20 μs
10 kV/10 mA (DC),
10 kV/20 mA (Pulsed)
Description
Module Selector
Test Fixture
High Voltage Bias-T
Thermal Test Enclosure
Device Capacitance Selector
Capacitance Test Fixture
On-wafer Gate Charge Measurement Adapter for 20 A/3 kV
On-wafer Gate Charge Measurement Adapter for N1265A