English
Language : 

T541D157M10AH6510 Datasheet, PDF (4/23 Pages) Kemet Corporation – T540/T541 COTS Polymer Electrolytic for High Reliability Applications, 2.5 - 63 VDC
KEMET Organic Capacitor (KO-CAP®) – High Reliability
T540/T541 COTS Polymer Electrolytic for High Reliability Applications, 2.5 – 63 VDC
Qualification
Test
Condition
Characteristics
Δ C/C
Within −20/+10% of initial value
Endurance
105°C at rated voltage, 2,000 hours
125°C at 2/3 rated voltage, 2,000 hours
DF
DCL **
≤ initial limit
1.25 x IL at 125ºC
ESR
2 x IL (105ºC); 5 x IL (125ºC)
Δ C/C
Within −20/+10% of initial value
Storage Life 125°C at 0 volts, 2,000 hours
DF
DCL **
Within initial limits
Within 2.0 x initial limit
ESR
Within 5.0 x initial limit
Humidity
60°C, 90% RH, 500 hours, rated voltage
60°C, 90% RH, 500 hours, no load
85°C, 85% RH, 1,000 hours, rated voltage ***
Δ C/C
DF
DCL
Within −5%/+35% of initial value
≤ initial limit
Within 1.5 x initial limit ***
Within 3.0 x initial limit
Temperature Stability
Extreme temperature exposure at a
succession of continuous steps at +25°C,
−55°C, +25°C, +85°C, +125°C, +25°C
Δ C/C
DF
DCL
+25°C
±5%
IL
IL
−55°C
±10%
IL
N/A
+85°C (1)
±20%
1.2 x IL
10 x IL
+125°C (2)
±30%
1.5 x IL
10 x IL
Δ C/C
Within −20/+5% of initial value
Surge Voltage
105°C, 1.32 x rated voltage, 33Ω resistance,
1,000 cycles
DF
Within initial limits
DCL
Within initial limits
ESR
Within initial limits
Mechanical Shock/
Vibration
Mil-Std-202, Method 213, Condition I, 100 G peak
Mil-Std-202, Method 204, Condition D, 10 Hz to 2,000
Hz, 20 G peak
Δ C/C
DF
DCL
Within ±10% of initial value
Within initial limits
Within initial limits
Additional qualifcation
testing per
MIL-PRF-55365/8
Please contact KEMET for more information
*IL = Initial limit
** The test voltage shall be maintained during the cool down from elevated test temperature to +25°C. After cool down, the capacitors shall be
discharged for a minimum of 5 minutes. DC leakage measurements are allowed at this time.
(1) ≥16V - D C/C = ±30%
(2) ≥16V - D C/C = ±40%
*** For Part Number with surge options 85, 86 and 87
Certification
DLA Drawing 04051 & 04052
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
T2077_T540-541 • 11/29/2016 4