KEMET Organic Capacitor (KO-CAP®) – High Reliability
T540/T541 COTS Polymer Electrolytic for High Reliability Applications, 2.5 – 63 VDC
Derating Guidelines
100%
95%
Rated Voltage
90%
85%
Recommended Application Voltage VR ≤ 10 V
80%
75%
Recommended Application Voltage VR > 10 V
70%
65%
60%
55%
50%
−55
25
45
85
105
125
Temperature (ºC)
Recommended Application Voltage
KOCAP’s are solid state capacitors that demonstrate no wearout mechanism when operated within their recommended
guidelines. While the KOCAP can be operated at full rated voltage, most circuit designers seek a minimum level of
assurance in long term reliability which should be demonstrated with data. A voltage derating can provide the desired level
of demonstrated reliability based on industry accepted acceleration models. Since most applications do require long term
reliability, KEMET recommends that designers consider a voltage derating, according the graphic above, for the maximum
steady state voltage.
Voltage
Rating
2 V ≤ VR ≤ 10 V
12.5 V ≤ VR ≤ 63 V
VR= Rated Voltage
Maximum
Recommended
Steady State Voltage
−55°C to 105°C
90% of VR
80% of VR
Maximum
Recommended
Steady State Voltage
105°C to 125°C
60% of VR ,See Chart
54% of VR ,See Chart
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
T2077_T540-541 • 11/29/2016 11