1.6.3 Ringing Switch: SW4
Parameter
Test Conditions
Symbol
VSW4 (differential) = RLINE to RRINGING
All-Off state.
+25°C
VSW (differential) = -255V to +210V
VSW (differential) = +255V to -210V
Off-State
Leakage Current
+85°C
VSW (differential) = -270V to +210V
ISW
VSW (differential) = +270V to -210V
-40°C
VSW (differential) = -245V to +210V
VSW (differential) = +245V to -210V
On-Resistance
ISW (on) = ±70mA, ±80mA
RON
On Voltage
ISW (on) = ± 1mA
VON
On-State
Leakage Current
Inputs set for ringing -Measure ringing
generator current to ground.
IRINGING
Steady-State Current* Inputs set for Ringing mode.
ISW
Surge Current*
Ringing switches on, all other switches
off. Apply ±1kV 10x1000s pulse with
ISW
appropriate protection in place.
Release Current
SW4 transition from on to off.
IRINGING
Logic inputs = GND
+25°C, VSW (RRINGING, RLINE)=±320V
Logic input to switch
output isolation
+85°C, VSW (RRINGING, RLINE)=±330V
ISW
-40°C, VSW (RRINGING, RLINE)= ±310V
Transient Immunity
100VPP Square Wave, 100Hz
(Not production tested - limits are
dV/dt
guaranteed by design and quality
control sampling audits.)
*Secondary protection and current limiting must prevent exceeding this parameter.
Minimum
-
-
-
-
-
-
-
-
1500
Typical
0.05
0.1
0.05
10
1.5
0.1
-
-
450
0.1
0.3
0.1
2100
CPC7695
Maximum
Unit
1
A
15

3
V
0.25
mA
150
mA
2
A
-
A
1
A
-
V/s
R00F
PRELIMINARY
7