1.8 Voltage and Power Specifications
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Voltage Requirements
VDD
-
VDD
4.5
5.0
5.5
V
VBAT1
-
VBAT
-19
-48
-72
V
1VBAT is used only for internal protection circuitry. If VBAT rises above-10V, the device will enter the All-Off state and will remain in the All-Off state until the battery
drops below -15V
Power Specifications
VDD = 5V, VBAT = -48V, VIH = 2.4V,
Power consumption
VIL = 0.4V, Measure IDD and IBAT
Talk and All-Off States
P
-
4.7
10.5
mW
All other states
P
-
5.2
10.5
mW
VDD current in Talk and
All-Off states
VDD = 5V, VBAT = -48V, VIH = 2.4V,
IDD
VDD current in all other VIL = 0.4V
states
IDD
-
-
0.9
2.0
mA
1.0
2.0
VBAT
current in
any
state
VDD = 5V, VBAT
VIL = 0.4V
=
-48V,
VIH
=
2.4V,
IBAT
-
4
10
A
R00F
PRELIMINARY