INTEGRATED CIRCUITS DIVISION
1.6 Switch Specifications
PRELIMINARY
1.6.1 Break Switches: SW1 and SW2
Parameter
Off-State
Leakage Current
On-Resistance
On-Resistance
Matching
DC current limit
Dynamic current limit
(t 0.5 s)
Logic input to switch
output isolation
Transient Immunity
Test Conditions
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25°C,
VSW (differential) = -320V to GND
VSW (differential) = +260V to -60V
+85°C,
VSW (differential) = -330V to GND
VSW (differential) = +270V to -60V
-40°C,
VSW (differential) = -310V to GND
VSW (differential) = +250V to -60V
ISW(on) = ±10mA, ±40mA,
RBAT and TBAT = -2V
+25°C
+85°C
-40°C
Per SW1 & SW2 On-Resistance test
conditions.
VSW (on) = ±10V
+25°C
+85°C
-40°C
Break switches on, all other switches
off. Apply ±1kV 10x1000s pulse with
appropriate protection in place.
Logic inputs = GND
+25°C, VSW (TLINE, RLINE) = ±320V
+85°C, VSW (TLINE, RLINE) = ±330V
-40°C, VSW (TLINE, RLINE) = ±310V
100VPP Square Wave, 100Hz
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
Symbol
ISW
RON
RON
ISW
ISW
ISW
dV/dt
Minimum
-
-
-
-
80
-
-
-
-
-
1500
Typical
0.1
0.3
0.1
14.5
20.5
10.5
0.15
225
150
400
2.5
0.1
0.3
0.1
2100
CPC7695
Maximum
Unit
1
A
-
28

-
0.55

-
mA
425
-
A
1
A
-
V/s
R00F
PRELIMINARY
5