English
Language : 

CPC7695_12 Datasheet, PDF (6/25 Pages) IXYS Corporation – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
PRELIMINARY
1.6.2 Ringing Return Switch: SW3
Parameter
Off-State
Leakage Current
On-Resistance
DC current limit
Dynamic current limit
(t 0.5 s)
Logic input to switch
output isolation
Transient Immunity
Test Conditions
VSW3 (differential) = TLINE to TRINGING
All-Off state.
+25°C,
VSW (differential) = -320V to GND
VSW (differential) = +260V to -60V
+85°C,
VSW (differential) = -330V to GND
VSW (differential) = +270V to -60V
-40°C,
VSW (differential) = -310V to GND
VSW (differential) = +250V to -60V
ISW(on) = ±0mA, ±10mA
+25°C
+85°C
-40°C
VSW (on) = ± 10V
+25°C
+85°C
-40°C
Ringing switches on, all other switches
off. Apply ±1kV 10x1000s pulse with
appropriate protection in place.
Logic inputs = GND
+25°C, VSW (TRINGING, TLINE)= ±320V
+85°C, VSW (TRINGING, TLINE)= ±330V
-40°C, VSW (TRINGING, TLINE) = ±310V
100VPP Square Wave, 100Hz
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
Symbol
ISW
RON
ISW
ISW
ISW
dV/dt
Minimum
-
-
-
70
-
-
-
1500
Typical
0.1
0.3
0.1
60
85
45
120
85
210
2.5
0.1
0.3
0.1
2100
CPC7695
Maximum
Unit
1
A
-
110

-
-
mA
-
A
1
A
-
V/s
6
PRELIMINARY
R00F