English
Language : 

CPC7695_12 Datasheet, PDF (10/25 Pages) IXYS Corporation – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
PRELIMINARY
1.6.6 Ringing Test Switch: SW8
Parameter
Off-State
Leakage Current
On-Resistance
DC current limit
Dynamic current limit
(t 0.5 s)
Logic input to switch
output isolation
Transient Immunity
Test Conditions
VSW8 (differential) = RTESTin to
RRINGING
All-Off state.
+25°C,
VSW (differential) = -320V to GND
VSW (differential) = +320V to GND
+85°C
VSW (differential) = -330V to GND
VSW (differential) = +330V to GND
-40°C
VSW (differential) = -310V to GND
VSW (differential) = +310V to GND
ISW (on) = ±10mA, ±40mA
+25°C
+85°C
-40°C
VSW (on) = ±10V
+25°C
+85°C
-40°C
Ringing test switches on, all other
switches off. Apply ±1kV, 10x1000s
pulse with appropriate protection in
place.
VSW8 (RRINGING, RTESTin)
Logic inputs = GND
+25°C, VSW = ±320V
+85°C, VSW = ±330V
-40°C, VSW = ±310V
100VPP Square Wave, 100Hz
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
Symbol Minimum
ISW
-
RON
-
-
ISW
80
-
ISW
-
ISW
-
dV/dt
1500
Typical
0.1
0.3
0.1
35
50
26
140
100
210
2.5
0.1
0.3
0.1
2100
CPC7695
Maximum
Unit
1
A
-
70

-
-
-
mA
250
-
A
1
A
-
V/s
10
PRELIMINARY
R00F