English
Language : 

X96011_08 Datasheet, PDF (8/18 Pages) Intersil Corporation – Temperature Sensor with Look-Up Table Memory and DAC
X96011
BYTE
ADDRESS
MSB
7
6
5
4
3
80h
NON-VOLATILE
1
IDS
NV13 ADCfiltOff
0
Iout
Direction
0: Source
1: Sink
CONTROL ADC
1, 3
filtering
VOLATILITY 0: On
0: VOLATILE 1: Off
1: NON-
VOLATILE
81h
VOLATILE OR
NON-VOLATILE
DIRECT ACCESS TO THE LUT
RESERVED RESERVED LDA5
LDA4
LDA3
2
0
LDA2
1
0
LDA1
LSB
0
0
REGISTER
NAME
CONTROL 0
LDA0
CONTROL 1
83h
VOLATILE OR
NON-VOLATILE
DIRECT ACCESS TO THE DAC
DDA7
DDA6
DDA5
DDA4
DDA3
DDA2
DDA1
DDA0
CONTROL 3
85h
NON-VOLATILE
0
0
DDAS
LDAS
0
Direct
Direct
Access Access
to dac
to lut
0: Disabled 0: Disabled
1: Enabled 1: Enabled
0
IFSO1
IFSO 0
CONTROL 5
R Selection
00: Reserved
01: Low Internal
10: Middle Internal
11: High Internal (Default)
86h
VOLATILE
WEL RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED CONTROL 6
Write Enable
Latch
0: Write
Disabled
1: Write
Enabled
ADC OUTPUT
87H
VOLATILE
AD7
AD6
AD5
AD4
AD3
AD2
AD1
AD0
STATUS
REGISTERS IN BYTE ADDRESSES 82H, 84H, AND 88H THROUGH 8FH ARE RESERVED.
REGISTERS BITS SHOWN AS 0 OR 1 SHOULD ALWAYS USE THESE VALUES FOR PROPER OPERATION.
FIGURE 4. CONTROL AND STATUS REGISTER FORMULA
8
FN8215.2
February 25, 2008