English
Language : 

ISL78201 Datasheet, PDF (8/23 Pages) Intersil Corporation – 40V 2.5A Regulator with Integrated High-side MOSFET for Synchronous Buck or Boost Buck Converter
ISL78201
Electrical Specifications Refer to the Block Diagram (page 4) and Typical Application Schematics (page 5). Operating conditions
unless otherwise noted: VIN = 12V, or VCC = 4.5V, TA = -40°C to +105°C. Typicals are at TA = +25°C.
Boldface limits apply across the operating temperature range, -40°C to +105°C. (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
(Note 6) TYP (Note 6) UNITS
Default PFM Current Threshold
MODE = VCC or floating
700
mA
INTERNAL HIGH-SIDE MOSFET
Upper MOSFET rDS(ON)
LOW-SIDE MOSFET GATE DRIVER
rDS(ON)_UP (Note 7) Limits apply for +25°C
127 140 mΩ
LGATE Source Resistance
100mA source current
3.5
Ω
LGATE Sink Resistance
100mA sink current
2.8
Ω
BOOST CONVERTER CONTROL
EXT_BOOST Boost_Turn-off Threshold Voltage
0.74 0.8 0.86 V
EXT_BOOST Hysteresis Sink Current
AUXVCC Boost Turn-off Threshold Voltage
IEXT_BOOST_HYS
2.1 3.2 4.2 µA
0.74 0.8 0.86 V
AUXVCC Hysteresis Sink Current
POWER GOOD MONITOR
IAUXVCC_HYS
2.1 3.2 4.2 µA
Overvoltage Rising Trip Point
Overvoltage Rising Hysteresis
Undervoltage Falling Trip Point
Undervoltage Falling Hysteresis
PGOOD Rising Delay
PGOOD Leakage Current
PGOOD Low Voltage
OVERCURRENT PROTECTION
VFB/VREF Percentage of reference point
VFB/VOVTRIP Percentage below OV trip point
VFB/VREF Percentage of reference point
VFB/VUVTRIP Percentage above UV trip point
tPGOODR_DELAY
PGOOD HIGH, VPGOOD = 4.5V
VPGOOD PGOOD LOW, IPGOOD = 0.2mA
104 110 116 %
3
%
84 90 96
%
3
%
128
cycle
10
nA
0.10
V
Default Cycle-by-cycle Current Limit Threshold
Hiccup Current Limit Threshold
OVERVOLTAGE PROTECTION
IOC_1
IOC_2
ILIMIT = GND or VCC or floating
Hiccup, IOC_2/IOC_1
3
3.6 4.2
A
115
%
OV 120% Trip Point
Active in and after soft-start
Percentage of Reference Point
LG = UG = LOW
120
%
OV 120% Release Point
Active in and after soft-start
Percentage of reference point
102.5
%
OV 110% Trip Point
Active after soft-start done
Percentage of reference point
LG = UG = LOW
110
%
OV 110% Release Point
Active after soft-start done
Percentage of Reference Point
102.5
%
OVER-TEMPERATURE PROTECTION
Over-temperature Trip Point
160
°C
Over-temperature Recovery Threshold
140
°C
NOTES:
6. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.
7. Wire bonds included.
Submit Document Feedback
8
FN8615.1