English
Language : 

ISL24201_14 Datasheet, PDF (5/12 Pages) Intersil Corporation – Programmable VCOM Calibrator with EEPROM
ISL24201
Electrical Specifications Test Conditions: VDD = 3.3V, AVDD = 18V, RSET = 5kΩ, R1 = 10kΩ, R2 = 10kΩ, (See Figure 5); unless otherwise
specified. Typicals are at TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to +85°C. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 6)
MAX
TYP (Note 6) UNITS
I2C TIMING
fCLK
tSCH
tSCL
tDSP
tSDS
tSDH
tBUF
tSTS
tSTH
tSPS
I2C Clock Frequency
I2C Clock High Time
I2C Clock Low Time
I2C Spike Rejection Filter Pulse Width
I2C Data Set Up Time
I2C Data Hold Time
I2C Time Between Stop and Start
I2C Repeated Start Condition Set-up
I2C Repeated Start Condition Hold
I2C Stop Condition Set-up
400
kHz
0.6
µs
1.3
µs
0
50
ns
250
ns
250
ns
200
µs
0.6
µs
0.6
µs
0.6
µs
CSDA SDA Pin Capacitance
10
pF
CS
SCL Pin Capacitance
10
pF
tW
EEPROM Write Cycle Time
100
ms
NOTE:
6. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
Application Information
AVDD
The ISL24201 provides the ability to adjust the VCOM voltage
during production test and alignment, under digital control, to
RA
minimize the flicker of an LCD panel. A digitally controlled
potentiometer (DCP), with 256 steps of resolution, adjusts the sink
current of the OUT pin. Figure 3 shows the VCOM adjustment using
R1 = RA
RB
VCOM
a mechanical potentiometer circuit and the equivalent circuit
R2 = RB+RC
replacement with the ISL24201.
The output is connected to an external voltage divider, as shown in
Figure 3, so that the ISL24201 will have the ability to reduce the
RSET = RARB + RARC
RC
20RB
voltage on the output by increasing the OUT pin sink current. The
amount of current sunk is controlled by the I2C serial interface.
VDD
AVDD
AVDD
ISL24201
or
R1
ISL24202
IOUT
OUT
SET
R2
RSET
VCOM
FIGURE 3. MECHANICAL ADJUSTMENT REPLACEMENT
5
FN7586.1
December 9, 2010