English
Language : 

X55060 Datasheet, PDF (19/23 Pages) Intersil Corporation – Dual Voltage Monitor with Integrated System Battery Switch and EEPROM
VCC to LOWLINE Timings
VCC
VTRIP1
0V
VOH
LOWLINE
VBATT
VOL
VTRIP1
0V
V2MON to V2FAIL Timings
V2MON
0V
V2FAIL
X55060
tRPD
tR
tRPD2
tR
tF
tRPD
VTRIP
tRPD2
VTRIP2
tF
VOUT
RESET/RESET/LOWLINE Output Timing
Symbol
tPURST
tRPD(1)
tRPD2(1)
tLR
tF(2)
tR(2)
VRVALID
tVB1
tVB2
Parameter
RESET/RESET Time-out Period
PUP = 0
PUP = 1
VTRIP1 to RESET/RESET (Power-down only) VTRIP1 to LOWLINE
VTRIP2 to V2FAIL
LOWLINE to RESET/RESET delay (Power-down only)
VCC/V2MON Fall Time
VCC/V2MON Rise Time
Reset Valid VCC
VBATT + 0.03 v to BATT-ON (logical 0)
VBATT - 0.03 v to BATT-ON (logical 1)
Notes: (1) This parameter is not 100% tested.
(2) This measurement is from 10% to 90% of the supply voltage.
(3) VCC = 5V at 25°C.
(4) Based on characterization data only.
Min. Typ.(3) Max. Unit
75
150
250
ms
500
800 1200
10
20
µs
10
20
µs
100 250(4) 800
ns
1000
µs
1000
µs
1
V
20(4)
µs
20(4)
µs
19
FN8133.0