English
Language : 

X9271_14 Datasheet, PDF (11/18 Pages) Intersil Corporation – Single, Digitally Controlled Potentiometer
X9271
Absolute Maximum Ratings
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Voltage on SCK, any Address Input,
with Respect to VSS. . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
V = |(VH - VL)| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5V
IW (10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Supply Voltage (VCC) Limits:
X9271 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ± 10%
X9271-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Thermal Information
Maximum Storage Temperature Range . . . . . . . . . .-65°C to +150°C
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . +300°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
Recommended Operating Conditions
Temperature Range (Commercial). . . . . . . . . . . . . . . . 0°C to +70°C
Temperature Range (Industrial) . . . . . . . . . . . . . . . . -40°C to +85°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
Analog Characteristics Across recommended industrial operating conditions unless otherwise specified.
LIMITS
SYMBOL
PARAMETER
MIN
MAX
(Note 17)
TYP
(Note 17)
UNITS
TEST CONDITIONS
RTOTAL
End to End Resistance
End to End Resistance
Tolerance
50
kΩ
U version
±20
%
Power Rating
50
mW
+25°C, each pot
IW
RW
RW
VTERM
Wiper Current
Wiper Resistance
Wiper Resistance
Voltage on any RH or RL Pin
VSS
Noise
Resolution
-120
0.4
±3
300
150
VCC
mA
W
W
V
dBVHz
%
IW = ± 3mA at VCC = 3V
IW = ± 3mA at VCC = 5V
VSS = 0V
Ref: 1V
Absolute Linearity (Note 10)
±1
MI
Rw(n)(actual) - Rw(n)(expected)
(Note 12) (Note 14)
Relative Linearity (Note 11)
±0.2
MI
Rw(n + 1) - [Rw(n) + MI] (Note 14)
(Note 12)
Temperature Coefficient of
RTOTAL
Ratiometric Temp.
Coefficient
±300
ppm/C
20
ppm/°C
CH/CL/CW
Potentiometer
Capacitance
10/10/25
pF
See macro model
NOTES:
10. Absolute linearity is used to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
11. Relative linearity is used to determine actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
12. MI = RTOT / 255 or (RH - RL) / 255, single pot.
13. During power-up, VCC > VH, VL, and VW.
14. n = 0, 1, 2, …,255; m = 0, 1, 2, …., 254.
Submit Document Feedback 11
FN8174.4
July 18, 2014