English
Language : 

ISL70517SEH Datasheet, PDF (11/27 Pages) Intersil Corporation – Precision test and measurement
ISL70517SEH
Typical Post Radiation Performance Curves VCC = VCO = 18V, VEE = VEO = -18V, VCM = 0V, RL = Open,
unless otherwise specified. Error bars (if shown) are based on minimum and maximum data. (Continued)
50
40
30 RFB = 120k
20
10
0
-10
-20
-30
-40
-50
0
VOSOUT 120k, BIASED
VOSOU T 120k, GROUNDED
SPEC LIMIT
SPEC LIMIT
25
50
75 ANNEAL
TOTAL DOSE, krad(Si) AT 0.01rad(Si)/s
-100
-110
PSRRI, BIASED
PSRRI, GROUNDED
SPEC LIMIT
-120
-130
-140 0
25
50
75 ANNEAL
TOTAL DOSE, krad(Si) AT 0.01rad(Si)/s
FIGURE 15. VosOUT (GAIN = 1) vs TOTAL DOSE
FIGURE 16. INPUT STAGE PSRR vs TOTAL DOSE
-80
-90
-100
PSRRO, BIASED
PSRRO, GROUNDED
SPEC LIMIT
-110
-120
-130
-140
-150
-160
0
25
50
75
ANNEAL
TOTAL DOSE, krad(Si) AT 0.01rad(Si)/s
FIGURE 17. OUTPUT STAGE PSRR vs TOTAL DOSE
Submit Document Feedback 11
FN8699.4
December 15, 2016