English
Language : 

ICB2FL02G Datasheet, PDF (50/55 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
2nd Generation FL-Controller for FL-Ballasts
Electrical Characteristics
5.3.3.5
Restart after Lamp Removal (RES)
Parameter
High Side Filament In Det.
RES Current Source
Symbol
VRES1
VRES2
VRES3
IRES1
IRES2
IRES3
IRES4
Limit Values
min. typ. max.
1.55 1.60 1.65
1.25 1.30 1.35
—
3.2 —
- 53.2 -42.6 -32.0
-44.2 -35.4 -26.6
- 26.6 -21.3 - 16.0
- 22.1 -17.7 -13.3
Unit
V
V
V
µA
µA
µA
µA
Test Condition
UVLO, VCC < VCCON
Run Mode
VRES = 1V ;
LVS1 = 5µA
VRES = 2V ;
LVS1 = 5µA
VRES = 1V ;
LVS1 = 30µA
VRES = 2V ;
LVS1 = 30µA
5.3.3.6
Lamp Voltage Sense (LVS1, LVS2)
Parameter
Symbol
Source Current before Startup
Enable Lamp Monitoring
Sink Current for Lamp Det.
Positive Clamping Voltage
AC EOLCurrent Threshold
Positive EOL Current Thr.
Negative EOL Current Thr.
ILVSSource
VLVSEnable1
ILVSSink
VLVSClamp
ILVSSourceAC
ILVSDCPos
ILVSDCNeg
Limit Values
min. typ. max.
- 5.0 - 3.0 - 2.0
350 530 750
8.0 12.0 18.0
—
6.5 —
190 210 230
34
42 50
- 50 - 42 - 34
Unit
µA
mV
µA
V
µApp
µA
µA
Test Condition
VLVS = 0V
1)
VLVS > VLVSClamp
@ ILVS = 300µA
ILVS > ILVSEOLpp EOL 1
ILVS > ILVSDCPos EOL 2
ILVS > ILVSDCNeg EOL 2
1) If VLVS < VLVS1Enable1 Monitoring is disabled
Preliminary Datasheet
Page 50 of 55
ICB2FL02G
V1.2