English
Language : 

ICB2FL02G Datasheet, PDF (49/55 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
2nd Generation FL-Controller for FL-Ballasts
Electrical Characteristics
5.3.3.3
Inverter Control Run (RFRUN)
Parameter
Fixed Start – Up Frequency
Duration of Soft Start
RFRUN Voltage in Run Mode
Run Frequency
Adjustable Run Frequency
RFRUN max. Current Range
Symbol
FStartUp
tSoftStart
VRFRUN
FRFRUN
FRFRUN1
FRFRUN2
FRFRUN3
IRFRUNmax
Limit Values
min. typ. max.
121.5 135 148.5
9
11 13.5
—
2.5 —
49
50 51
—
20 —
—
40 —
—
100 —
— -1000 - 650
Unit
kHz
ms
V
kHz
kHz
kHz
kHz
µA
Test Condition
1)
@ 100µA<IRFRUN<600µA
RRFRUN = 10kΩ
IRFRUN= - 100 µA
IRFRUN= - 200 µA
IRFRUN= - 500 µA
@ VRFRUN = 0V
1) Shift Start Up Frequency to Preheating Frequency
5.3.3.4
Inverter Control Preheating (RFPH, RTPH)
Parameter
RFPH Voltage Preheating
Preheating Frequency
RFPH max. Current Range
Current for set Preh. Time
Preheating Time
Symbol
VRFPH
FRFPH1
IRFPHmax
IRTPH
tRTPH1
tRTPH2
tRTPH3
tRTPH4
tRTPH5
Limit Values
min. typ. max.
—
2.5 —
97 100 103
— -1000 - 550
— - 100 —
950 1000 1050
50 100 150
—
500 —
— 2000 —
— 2500 —
Unit
V
kHz
µA
µA
ms
ms
ms
ms
ms
Test Condition
VRFPH = 0V in Run Mode
RRFPH = RRFRUN = 10kΩ
@ VRFPH = 0V
RRTPH1 = 10kΩ
RRTPH2 = 1kΩ
RRTPH3 = 5kΩ
RRTPH4 = 20kΩ
RRTPH5 = 25kΩ
Preliminary Datasheet
Page 49 of 55
ICB2FL02G
V1.2