TLE5012_10 Datasheet, PDF (41/64 Pages) Infineon Technologies AG – GMR-Based Angular Sensor for Rotor-Position Sensing
Field
DSPU_HOLD
IIF_MOD
SIL Register
TLE5012
Specifications
Bits
Type Description
2
w
Hold DSPU Operation
If DSPU is on hold, no WD reset is performed by DSPU.
Deactivate watchdog with AS_WD before setting DSPU
on hold.
0B DSPU in normal schedule operation
1B DSPU is on hold
Reset: 0B
1:0
w
Incremental Interface Mode
00B IIF disabled
01B A/B operation with Index on DATA
10B Step/Direction operation with Index on DATA
11B not allowed
Reset: 01B
SIL
SIL Register
15
14
13
FILT_PA
R
FILT_IN
V
w
w
7
6
5
Res
ADCTV_E
N
w
Field
Bits
FILT_PAR
15
FILT_INV
14
FUSE_REL
10
Offset
07H
11
Res
3
ADCTV_Y
w
Reset Value
0000H
10
FUSE_RE
L
w
2
9
8
Res
0
ADCTV_X
w
Type
w
w
w
Description
Filter Parallel
0B filter parallel disabled
1B filter parallel enabled (source: X-value)
Reset: 0B
Filter Inverted
0B filter inverted disabled
1B filter inverted enabled
Reset: 0B
Fuse Reload
0B fuse reload disabled
1B fuse parameters reloaded to DSPU at next cycle
start
Reset: 0B
Final Data Sheet
41