TLE5012_10 Datasheet, PDF (35/64 Pages) Infineon Technologies AG – GMR-Based Angular Sensor for Rotor-Position Sensing
Field
S_ADCT
S_MAGOL
S_XYOL
S_OV
S_DSPU
S_FUSE
S_VR
Final Data Sheet
TLE5012
Specifications
Bits
Type Description
9
ru
Status ADC-Test1)
Check of signal path with test vectors. All test vectors at
startup tested. Activation in operation via AS_ADCT
possible.
0B Test vectors OK
1B Test vectors out of limit
Reset: 0B
7
ru
Status Magnitude Out of Limit1)
Cyclic check of available magnetic field strength.
Deactivation via AS_VEC_MAG.
0B GMR-magnitude OK
1B GMR-magnitude out of limit
Reset: 0B
6
ru
Status X,Y Data Out of Limit1)
Cylcic check of X and Y raw values. Deactivation via
AS_VEC_XY
0B X,Y data OK
1B X,Y data out of limit (>23230 digits)
Reset: 0B
5
ru
Status Overflow1)
Cyclic check of DSPU overflow. Deactivation via AS_OV.
0B No DSPU overflow occurred
1B DSPU overflow occurred
Reset: 0B
4
ru
Status Digital Signal Processing Unit
Check of DSPU, CORDIC and CAPCOM at startup.
Activation in operation via AS_DSPU possible.
0B DSPU self-test OK
1B DSPU self-test not OK, or self-test is running
Reset: 0B
3
ru
Status Fuse CRC1)
Cyclic CRC check of laser-cut-fuses. Deactivation via
AS_FUSE and disabled by activated autocalibration.
Note: Changing of fused parameters results in new CRC,
which differs from stored CRC --> Fuse CRC fail
0B Fuse CRC OK
1B Fuse CRC fail
Reset: 0B
2
ru
Status Voltage Regulator1)
Permanent check of internal and external supply
voltages. Deactivation via AS_VR
0B Voltages OK
1B VDD overvoltage; VDD undervoltage; VDD-off; GND-
off; or VOVG; VOVA; VOVD too high
Reset: 0B
35