English
Language : 

TLE5012_10 Datasheet, PDF (22/64 Pages) Infineon Technologies AG – GMR-Based Angular Sensor for Rotor-Position Sensing
TLE5012
Specifications
3.4.3 GMR Parameters
All parameters apply over BXY = 30mT and TA = 25°C, unless otherwise specified.
Table 8 Basic GMR parameters
Parameter
Symbol
Values
Min. Typ. Max.
X, Y output range
X, Y amplitude 1)
X, Y synchronism 2)
X, Y offset 3)
X, Y orthogonality error
RGADC
AX, AY
k
OX, OY
Φ
-
-
6000 9500
3922 -
87.5 100
-2048 0
-11.25 0
±23230
15781
20620
112.49
+2047
+11.24
X, Y without field
1) See Figure 11
X0, Y0
-5000 -
+5000
2) k = 100*(AX/AY)
3) OY=(YMAX + YMIN) / 2; OX = (XMAX + XMIN) / 2
4) Not subject to production test - verified by design/characterization
Unit Note / Test Condition
digits
digits
digits
%
digits
°
digits
4)
operating range
without magnet 4)
VY
0 0°
+A
90°
180°
-A
Offset
270°
360°
Angle
Figure 11 Offset and amplitude definition
Final Data Sheet
22
V 1.0, 2010-11