English
Language : 

ICE3AR10080CJZ Datasheet, PDF (32/33 Pages) Infineon Technologies AG – Off-Line SMPS Current Mode Controller with integrated 800V CoolMOS® and Startup cell (brownout & CCM) in DIP-7
CoolSET®-F3R80
ICE3AR10080CJZ
Schematic for recommended PCB layout
b. Spark Gap 1 and Spark Gap 2, Live / Neutral to GROUND:
These 2 Spark Gaps can be used when the lightning surge requirement is >6KV.
230Vac input voltage application, the gap separation is around 5.5mm
115Vac input voltage application, the gap separation is around 3mm
2. Add Y-capacitor (C2 and C3) in the Live and Neutral to ground even though it is a 2-pin input
3. Add negative pulse clamping diode, D11 to the Current sense resistor, R12:
The negative pulse clamping diode can reduce the negative pulse going into the CS pin of the CoolSET and
reduce the abnormal behavior of the CoolSET. The diode can be a fast speed diode such as IN4148.
The principle behind is to drain the high surge voltage from Live/Neutral to Ground without passing through
the sensitive components such as the primary controller, IC11.
Version 2.0
32