ICE3GS03LJG Datasheet, PDF (14/25 Pages) Infineon Technologies AG – Of f-Line SMPS Current Mode Controller wi th integrated 500V Startup Cell
F3 PWM controller
ICE3GS03LJG
Functional Description
The Propagation Delay Compensation is realized by
means of a dynamic threshold voltage Vcsth (see Figure
21). In case of a steeper slope the switch off of the
driver is earlier to compensate the delay.
3.7
Control Unit
The Control Unit contains the functions for Active Burst
Mode, Auto Restart Mode and Latched Off Mode. The
Active Burst Mode and the Auto Restart Mode both
have 20ms internal Blanking Time. For the Auto
Restart Mode, a further extendable Blanking Time is
achieved by adding external capacitor at BL pin. By
means of this Blanking Time, the IC avoids entering
into these two modes accidentally. Furthermore those
buffer time for the overload detection is very useful for
the application that works in low current but requires a
short duration of high current occasionally.
3.7.1
Basic and Extendable Blanking Mode
BL
# CBK
5.0V
IBK
0.9V
1
S1
G2
Soft Start
block
blanking time is passed, the switch S1 is opened by
G2. Then the 0.9V clamped voltage at BL pin is
charged to 4.0V through the internal IBK constant
current. Then G5 is enabled by comparator C3. After
the 30us spike blanking time, the Auto Restart Mode is
activated.
For example, if CBK = 0.22mF, IBK = 13mA
Blanking time = 20ms + CBK x (4.0 - 0.9) / IBK = 72ms
The 20ms blanking time circuit after C4 is disabled by
the soft start block before start up and the maximum
CBK capacitor is restricted to use less than 1.3mF such
that the controller can start up properly.
The Active Burst Mode has basic blanking mode only
while the Auto Restart Mode has both the basic and the
extendable blanking mode.
3.7.2
Active Burst Mode
The IC enters Active Burst Mode under low load
conditions. With the Active Burst Mode, the efficiency
increases significantly at light load conditions while still
maintaining a low ripple on VOUT and a fast response on
load jumps. During Active Burst Mode, the IC is
controlled by the FB signal. Since the IC is always
active, it can be a very fast response to the quick
change at the FB signal. The Start up Cell is kept OFF
in order to minimize the power loss.
Internal Bias
C3
4.0V
Spike
Blanking
30us
20 ms Blanking
Time
Current
Limiting
&
G10
4.2V
C4
&
20ms
G5
Blanking
Time
Auto
Restart
Mode
FB
C5
1.23V
20ms
Blanking
Time
&
Active
G6
Burst
Mode
Control Unit
Figure 22 Basic and Extendable Blanking Mode
There are 2 kinds of Blanking mode; basic mode and
the extendable mode. The basic mode has an internal
pre-set 20ms blanking time while the extendable mode
has extended blanking time to basic mode by
connecting an external capacitor to the BL pin. For the
extendable mode, the gate G5 is blocked even though
the 20ms blanking time is reached if an external
capacitor CBK is added to BL pin. While the 20ms
4.2V
C4
FB
C5
1.23V
Active
Burst
&
Mode
G6
C6a
3.5V
C6b
3.0V
&
G11
Control Unit
Figure 23 Active Burst Mode
The Active Burst Mode is located in the Control Unit.
Figure 23 shows the related components.
Version 2.0
14