English
Language : 

TLE4926C-HTNE6747 Datasheet, PDF (13/27 Pages) Infineon Technologies AG – Dynamic Differential Hall Effect Sensor
2.2.12 Frequency range
f
0.001
2.2.13 Oscillator frequency
fOSC
2.2.14 Offset recalibration time treset
after last output change
2.2.15 Clamping voltage
VS-Pin
2.2.16 Clamping voltage Q- Pin
2.2.17 Analog reset voltage
VSclamp
VQclamp
VsReset
1.08
625
24
24
1.34
780
27.5
27.5
2.35
8
1.68
970
2.9
TLE4926C-HTN E6747
kHz Operation below
1Hz11
MHz -
ms Output locked to state
before recalibration
V IS = 20mA < 5min.
V IQ = 20mA < 5min.
V-
Note: The listed AC/DC and magnetic characteristics are ensured over the operating range of the
integrated circuit. Typical characteristics specify mean values expected over the production
spread. If not other specified, typical characteristics apply at Tj = 25 °C and VS = 12 V.
2.3 Magnetic Characteristics in Running Mode
No.
Parameter
Symbol min typ max Unit
Remarks
2.3.1
Bias preinduction
B0
-500
2.3.2 Differential bias induction ∆B0
-30
500 mT -
30 mT -
2.3.3
2.3.4
Minimum signal
amplitude
Maximum signal
amplitude
∆Bmin 0.55
∆Bmax
1.5 mT
100 mT Additional to B0 12.
2.3.5
Resistivity against
∆Bmin -0.2
mechanical stress (piezo)
0.2 mT F= 2N
Note: The listed characteristics are ensured over the operating range of the integrated circuit. Typical
characteristics specify mean values expected over the production spread. If not otherwise
specified, typical characteristics apply at Tj=25°C and the given supply voltage.
3.1 Self-calibration Characteristics
No.
Parameter
Symbol min
typ
max Unit
Remarks
3.1.1 No. of magnetic edges
for first output switching
nStart
2
- latest 2nd magnetic
edge will cause output
switching
3.1.2 No. of magnetic edges nCalib
to enter calibrated mode
613
- Low phase accuracy
permitted. See 3.1.7
7th edge with high
accuracy (calibrated)
11 Output will switch if magnetic signal is changing more that 2x∆Bmin within offset recalibration time
even below 1Hz once per magnetic edge, increased phase error is possible.
12 Exceeding this limit might result in decreased duty cycle performance. With higher values the
internal measured signal will be clipped. This will decrease the phase accuracy.
13 Valid for sinusoidal signal without noise influence
Data Sheet
Page 13 of 27