English
Language : 

BTM7710GP Datasheet, PDF (10/18 Pages) Infineon Technologies AG – TrilithIC
BTM7710GP
5
Electrical Characteristics
5.1
Absolute Maximum Ratings
Absolute Maximum Ratings1)
– 40 °C < Tj < 110 °C
Pos. Parameter
Symbol Limit Values
min. max.
High-Side-Switches (Pins DHVS, IH1,2 and SH1,2)
5.1.1
5.1.2
Supply voltage
Supply voltage for full short circuit
protection
VS
– 0.3 42
VS(SCP) –
28
5.1.3 HS-drain current
5.1.4 HS-input current
5.1.5 HS-input voltage
Status Output ST
IS
– 10
2)
IIH
–5
5
VIH
– 10 16
5.1.6 Status pull up voltage
VST
5.1.7 Status Output current
IST
Low-Side-Switches (Pins DL1,2, IL1,2 and SL1,2)
– 0.3 5.4
–5
5
5.1.8 Drain-Source-Clamp voltage
VDSL
55
–
5.1.9 LS-drain current
5.1.10
IDL
– 12 12
–
20
5.1.11
–
30
5.1.12 LS-input voltage
Temperatures
5.1.13 Junction temperature
5.1.14 Storage temperature
ESD Protection3)
5.1.15 Input LS-Switch
5.1.16 Input HS-Switch
5.1.17 Status HS-Switch
5.1.18 Output LS and HS-Switch
VIL
– 20 20
Tj
– 40 110
Tstg
– 55 150
VESD
–
0.3
VESD
–
1
VESD
–
2
VESD
–
8
1) Not subject to production test; specified by design
2) Internally limited
3) ESD susceptibility HBM according to EIA/JESD22-A114-B (1.5kΩ, 100pF)
Unit Remarks
V–
V–
A TA = 25°C; tP < 100 ms
mA Pin IH1 and IH2
V Pin IH1 and IH2
V–
mA Pin ST
V VIL = 0 V; ID ≤ 1 mA
Tj = 25°C
A TC = 125°C; DC
A TC = 85°C; tP < 100 ms;
duty cycle < 0.1
A TC = 85°C; tP < 1 ms;
duty cycle < 0.1
V Pin IL1 and IL2
°C –
°C –
kV –
kV –
kV –
kV all other pins connected
to Ground
Note: Stresses above the ones listed here may cause permanent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.
Datasheet
10
Rev. 1.0, 2008-07-07