English
Language : 

9ZXL1231_16 Datasheet, PDF (8/18 Pages) Integrated Device Technology – 12-output DB1200ZL
9ZXL1231 DATASHEET
Electrical Characteristics–DIF Low Power HCSL Outputs
TAMB = TCOM or TIND, unless noted., Supply Voltages per normal operation conditions, See Test Loads for Loading Conditions
PARAMETER
Slew rate
Slew rate matching
SYMBOL
dV/dt
ΔdV/dt
CONDITIONS
TAMB = TCOM, Scope averaging on
TAMB = TIND Scope averaging on
Slew rate matching, Scope averaging on
MIN TYP MAX UNITS NOTES
1.5 3.3
4 V/ns 1,2,3
1.5 3.1 4.5 V/ns 1,2,3
7
20
% 1,2,4
Voltage High
Voltage Low
VHigh
VLow
Statistical measurement on single-ended signal 660 778 850
using oscilloscope math function. (Scope
mV
averaging on)
-150 0 150
Max Voltage
Min Voltage
Crossing Voltage (abs)
Crossing Voltage (var)
Vmax
Vmin
Vcross_abs
Δ-Vcross
Measurement on single ended signal using
absolute value. (Scope averaging off)
Scope averaging off
Scope averaging off
868 1150 mV
-300 -64
250 430 550 mV 1,5
17 140 mV 1,6
1Guaranteed by design and characterization, not 100% tested in production.
2 Measured from differential waveform
3 Slew rate is measured through the Vswing voltage range centered around differential 0V. This results in a +/-150mV window around
differential 0V.
4 Matching applies to rising edge rate for Clock and falling edge rate for Clock#. It is measured using a +/-75mV window centered on
the average cross point where Clock rising meets Clock# falling. The median cross point is used to calculate the voltage thresholds the
oscilloscope is to use for the edge rate calculations.
5 Vcross is defined as voltage where Clock = Clock# measured on a component test board and only applies to the differential rising
edge (i.e. Clock rising and Clock# falling).
6 The total variation of all Vcross measurements in any particular system. Note that this is a subset of Vcross_min/max (Vcross
absolute) allowed. The intent is to limit Vcross induced modulation by setting Δ-Vcross to be smaller than Vcross absolute.
7 At default SMBus settings.
Electrical Characteristics–Current Consumption
TAMB = TCOM or TIND, unless noted., Supply Voltages per normal operation conditions, See Test Loads for Loading Conditions
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS NOTES
Operating Supply Current
Power Down Current
1. Includes VDDR if applicable
IDDA
IDD
IDDIO
IDDA
IDD
IDDIO
VDDA, PLL Mode@100MHz
VDDA, PLL Bypass Mode@100MHz
All other VDD pins
VDDIO for DIF outputs, if applicable
VDDA, PLL Mode@100MHz
VDDA, PLL Bypass Mode@100MHz
All other VDD pins
VDDIO for DIF outputs, if applicable
18 20
mA
1
6
10
mA
1
16 25
mA
91 110
mA
3
5
mA
1
3
5
mA
1
0.01 1
mA
0.01 0.3
mA
12-OUTPUT DB1200ZL
8
REVISION J 05/25/16