IC-NQL Datasheet, PDF (9/24 Pages) IC-Haus GmbH – 13-bit Sin/D CONVERTER WITH SSI INTERFACE
iC-NQL
13-bit Sin/D CONVERTER WITH SSI INTERFACE
Rev B1, Page 9/24
OPERATING REQUIREMENTS: SSI INTERFACE
Operating Conditions: VDD = 5 V ±10 %, Ta = -25 ... 85 °C; input levels lo = 0 ... 0.45 V, hi = 2.4 V ... VDD
Item Symbol Parameter
Conditions
Fig.
No.
I001 TCLK
Permissible Clock Period
CFGTOS = 0x01
4
I002 tCLKhi
Clock Signal Hi Level Duration
4
I003 tCLKlo
Clock Signal Lo Level Duration
4
Min.
250
25
25
Max.
2x ttos
ttos
ttos
Unit
ns
ns
ns
Figure 4: Timing diagram of SSI output.