IC-NQC_11 Datasheet, PDF (9/29 Pages) IC-Haus GmbH – 13-bit Sin/D CONVERTER WITH SIGNAL CALIBRATION
iC-NQC
preliminary
13-bit Sin/D CONVERTER WITH SIGNAL CALIBRATION
Rev D1, Page 9/29
OPERATING REQUIREMENTS: I/O Interface
Operating Conditions: VDD = 5 V ±10 %, Ta = -25 ... 85 °C; input levels lo = 0 ... 0.45 V, hi = 2.4 V ... VDD
Item Symbol Parameter
Conditions
Fig.
No.
SSI Protocol
I001 TMAS
Permissible Clock Period
ttos according to Table 44
4
I002 tMASh
Clock Signal Hi Level Duration
4
I003 tMASl
Clock Signal Lo Level Duration
4
BiSS C Protocol
I004 TMAS
Permissible Clock Period
ttos according to Table 34
5
I005 tMASh
Clock Signal Hi Level Duration
5
I006 tMASl
Clock Signal Lo Level Duration
5
Min.
250
25
25
100
25
25
Unit
Max.
2x ttos
ns
ttos
ns
ttos
ns
2x ttos
ns
ttos
ns
ttos
ns
Figure 3: Timing diagram in SSI protocol.
Figure 4: Timing diagram in BiSS C protocol.