OPERATING REQUIREMENTS: SPI and I²C Interface
Operating Conditions: VB = 2.8 . . . 8 V , Tj = -40 . . . 125 °C
Item Symbol Parameter
No.
Conditions
SPI / I²C Interface Timing
I001 tsCCL
Setup Time:
INS/WKR = lo
NCS/A1 hi → lo before SCLK lo → hi
I002 tsDCL
Setup Time:
MOSI/A0 stable before SCLK/SCL lo
→ hi
INS/WKR = lo
I003 thDCL
Hold Time:
INS/WKR = lo
MOSI/A0 stable after SCLK/SCL lo →
hi
I004 tCLh
Signal Duration SCLK/SCL hi
I005 tCLI
Signal Duration SCLK/SCL lo
I006 thCLC
Hold Time: NCS/A1 lo after SCLK/SCL INS/WKR = lo
lo → hi
I007 tCSh
Signal Duration NCS/A1 hi
INS/WKR = lo
I008 tpCLD
Propagation Delay:
MISO/SDA stable after SCLK/SCL hi
→ lo
V(VDD) > 3 V, Cload = 10 pF, no external
pull-up
I009 f(SCLK) SPI clock frequency
I010 f(SCL) I²C clock frequency
Min.
20
20
Unit
Max.
ns
ns
5
ns
5
µs
5
µs
5
ns
20
ns
0
30
ns
10
MHz
400
kHz