English
Language : 

IC-PR Datasheet, PDF (12/18 Pages) IC-Haus GmbH – REFLECTIVE OPTO ENCODERS
iC-PR Series
REFLECTIVE OPTO ENCODERS
DIGITAL OPERATION MODES
INTERPOLATION FACTOR AND INDEX GATING
Rev A3, Page 12/18
Mode DX1
GNDA
VCC
SEL1
iC-PRxxxx
SEL2
VCC
Mode DX2
SEL1
GNDA
iC-PRxxxx
SEL2
5.625°/CPR (digital hysteresis)
A+
B+
Z+ (Ungated)
Z+ (B-Gated)
Z+ (AB-Gated)
A+
B+
Z+ (Ungated)
Z+ (B-Gated)
Z+ (AB-Gated)
Mode DX4
VCC
GNDA
R
R
SEL1
iC-PRxxxx
SEL2
GNDA
VCC
Mode DX8
SEL1
VCC
iC-PRxxxx
SEL2
A+
B+
Z+ (Ungated)
Z+ (B-Gated)
Z+ (AB-Gated)
A+
B+
Z+ (Ungated)
Z+ (B-Gated)
Z+ (AB-Gated)
VCC
VCC
Mode DX16
SEL1
R
iC-PRxxxx
SEL2
R
GNDA
0° (code disc angle)
A+
B+
Z+ (Ungated)
Z+ (B-Gated)
Z+ (AB-Gated)
Figure 8: Digital operation modes (interpolation and index gating). Complementary signals
A-, B- and Z- not shown.