English
Language : 

IC-PR Datasheet, PDF (11/18 Pages) IC-Haus GmbH – REFLECTIVE OPTO ENCODERS
iC-PR Series
REFLECTIVE OPTO ENCODERS
ANALOG / MIXED OPERATION MODES
Rev A3, Page 11/18
VCC
R
R
Mode A250
SEL1
GNDA
GNDA
iC-PRxxxx
SEL2
COS+
SIN+
Z-
Z+
VREF +/- 250 mV
VREF
VCC
Mode AAMP
R
R
VCC
GNDA
SEL1
iC-PRxxxx
SEL2
COS+
SIN+
Vout()d + Vout()dc +/- 250 mV
Z-
Vout()d
Z+
VCC
R
R
GNDA
Mode A500DZ
SEL1
iC-PRxxxx
SEL2
COS+
SIN+
VREF +/- 500 mV
Z-
Ungated
Z+
Digital levels
Figure 7: Analog / mixed operation modes. Complementary signals COS- and
SIN- not shown.
• Vout()d is the dark signal level of the analog sig-
nals. It is independent of illumination but propor-
tional to temperature.
• Vout()dc is the dc-level of the analog signals with
respect to the dark signal level. It is proportional
to illumination but independent of temperature.
• The permissible load current for the analog out-
puts is specified as parameter 211 in the Electrical
Characteristics.
• For correct functionality of the Z-index, program-
ming pin VZ has to be set to a proper value as de-
scribed in section INDEX DETECTION THRESH-
OLD.