Chapter 5. Software
4.4 Option Menu
To execute each command, select [ALT]-[O] key and press the highlighted
character in each command line. Or select the menu and press the [Enter]
key.
MCU Select
Setup
: Select according to the kind of micom. Able to select on of
GMS30004, 30012, 30112, 30120 or 30140 among GMS300
series. Once the command is executed, the window
indicating the characteristics of each micom is open. Press
Left, Right, Up Down key to select the micom to work.
: Set the execution mode of selected micom. It has the same
function as > SET command of In-line command. Once the
function is executed, a small <Setup> window is open.
Position the cursor in either of I/O Input and Output mode,
Symbol, Execution Mode of Watch Dog Timer with the item to
change. Assign the corresponding execution mode with Left,
Right arrow key.
I/O Input [pi]
I/O Output
Execution Mode to be Assigned in <Setup>
= [0] Port Input from I/O register
[1] Port input from keyboard
[2] Port input from file (PORTIN.DAT)
= [0] No display
[1] Display
[2] Display & Break
Symbol
= [0] Search
[1] Unsearch
Watch Dog Timer = [0] OFF
[1] ON (No option)
[2] ON (Option)
5- 9