GMS30004 Datasheet, PDF (58/158 Pages) Hynix Semiconductor – 4-BIT SINGLE CHIP MICROCOMPUTERS
Chapter 5. Software
3. Screen Organization of Simulator
Screen is basically organized with four windows; Memory, Source, Command and
Register. Source and Command windows can be enlarged up to the full screen
size (CTRL-[F10]). Movement between windows is made by [F6].
3.1 Memory Window
Data memory contents of the currently selected micom is displayed. 32 nibble
data values of 00~1F(h) addresses are displayed.
3.2 Source Window
The contents of *.RHX file called by load command is displayed in the state of
being disassembled. Addresses are displayed randomly in the state of
polynomial together with instruction code and mnemonic. If *.CRF file is
called, label is displayed at the corresponding position. Display position of
source program is adjustable with Up/Down arrow keys and Page Up/Down
keys.
3.3 Command Window
All kinds of commands provided by simulator is executed by In-line command,
and the execution results of the commands are displayed. Command window
size is adjustable with [CTRL]-[F10].
5- 4