Precautions and recommendations
[ Coutions for ground plate assembly ]
1. Attach a ground plate separately provided as FX15S-41P-GND after the cable assembly process.
2. Place the ground plate onto the connector horizontally and pinch the two components from top and bottom with your fingers.
Ground plate
(FX15S-41P-GND)
A
Pinch from top and bottom with fingers
A
qAssembly
wHorizontally
from the top
ePinch with fingers
3. Check the six fitting points after assembly and make sure that they are all correctly fitted together.
Fitting
Fitting
Fitting
Fitting
A
Fitting
Fitting
How to check fitting points
(Cut section of fitting points)
Ground plate hooks the
protrusion of connector housing
Ground plate does not hook the
protrusion of connector housing
OK
NG
[ Soldering to ground plate ]
1. Solder down the metal bar of the cable and ground plate after the assembly of the ground plate to enhance grounding
capability and to protect against vertical cable puling forces.
Soldering
Soldering
A