FX15 Datasheet, PDF (16/24 Pages) Hirose Electric – 1mm Pitch Wire-to-Board Connectors supporting LVDS signal
FX15 Series●1mm Pitch Wire-to-Board Connectors supporting LVDS signal
Precautions and recommendations
◆Wire termination
The following documents will be needed in order to perform the cable terminations.
1Basic cable termination and crimp requirements (general explanations).
2Contact crimp termination machine instruction manual (Explanation of the press)
3Applicator parts installation table (Applicator installation explanation)
4Crimp conditions table (Crimp height/Tensile strength standard values)
5Crimp quality fundamentals manual (Bell-mouth dimensions, bent up, bent down, rolling, etc.)
* Correct cable preparation and crimp termination is based on understanding and following the procedures in the above documents.
◆Insertion of the crimp contacts in the housing
Crimp contacts are inserted in the housing as illustrated below.
Exercising caution when inserting, align the retention tab of the contact with the corresponding molded-in lance in the
housing’s contact cavity and push the contacts in.
Make sure that the contact is fully inserted and the retention tab clears the molded-in lance.
Molded-in lance
Retention tab
Molded-in lance
Retention tab facing up
Crimp side
Molded-in lance
Retention tab facing down
◆Verify that the retention tabs clear the molded-in lances as shown on the illustration below.
Retention tab
Light pull on the wire, with force NOT EXCEEDING 3N will also verify the correct contact insertion.
◆Removal of the contacts
Using sharp-pointed tool of appropriate size gently lift the molded-in tab and pull-out the terminated contacts.
Excersize caution as NOT to damage the molded-in lance.
Should the damage occur, the entire housing will need to be replaced.
1
2