English
Language : 

FX15 Datasheet, PDF (19/24 Pages) Hirose Electric – 1mm Pitch Wire-to-Board Connectors supporting LVDS signal
FX15 Series●1mm Pitch Wire-to-Board Connectors supporting LVDS signal
Precautions and recommendations
5. After soldering, check that no defect is found at soldered area.
Examples of correct soldered and defective soldered state are shown below.
Solder shortage
A
AA
solder bridge
B
BB
A
Correct soldering
B
Floating
[ Coutions for potting process ]
1. Protect the soldered area by UV cured resin (referred as "potting" hereafter), in order to prevent cable breakage during
cabling and other issues.
2. Apply 3033 manufactured by THREEBOND CO., LTD. or any equivalent product for potting.
Follow the instruction of the potting manufacturer for UV curing exposure.
3. Refer to the following conditions the potting area.
Number of contacts
A
41
23.7
51
28.7
A
0
-3
1.25
0
-0.75
A
Enlarged view
4. Use extreme care in handling the soldered and potted assembly. Too much stress applied to the cable could break it.