English
Language : 

FH26-13S-0.3SHW Datasheet, PDF (2/16 Pages) Hirose Electric – 0.3mm Contact Pitch, 1mm above the board, Flexible Printed Circuit ZIF Connectors
sSpecifications
Rating
Current rating 0.2A DC
Voltage rating 30V AC
Operating temperature range -55 ç to +85ç (Note 1)
Operating humidity range Relative humidity 90%
max. (No condensation)
Storage temperature range -10ç to +50ç (Note 2)
Storage humidity range Relative humidity 90% max.
Recommended FPC :
Thickness: = 0.2±0.03mm tin-lead plated (Note 3)
Item
Specification
Conditions
1. Insulation resistance 50 M ohms min.
100 V DC
2. Withstanding voltage No flashover or insulation breakdown.
90 V AC /one minute
3. Contact resistance
4. Durability
(Insertion/ withdrawal)
5. Vibration
6. Shock
100 m ohms max.
* Including FPC conductor resistance
Contact resistance: 100 m ohms max.
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1µs or more.
Contact resistance: 100 m ohms max.
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1µs. min.
Contact resistance: 100 m ohms max.
No damage, cracks, or parts dislocation.
1 mA
10 cycles
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 10 cycles, 3
directions.
Acceleration of 981 m/s2, 6 ms duration, sine half-wave waveform,
3 cycles in each of the 3 axis
7. Humidity
(Steady state)
8. Temperature cycle
9. Resistance to soldering heat
Contact resistance: 100 m ohms max.
Insulation resistance: 50 M ohms min.
No affect on appearance or performance.
Contact resistance: 100 m ohms max.
Insulation resistance: 50 M ohms min.
No damage, cracks, or parts looseness.
No deformation of components affecting performance.
96 hours at temperature of 40±2ç and humidity of 90% to 95%.
Temperature: -55 ç/+15ç to +35ç/+85ç/+15ç to +35ç
Time: 30 / 2 to 3 / 30 / 2 to 3 (Minutes)
5 cycles
Reflow: At the recommended temperature profile
Manual soldering: 350ç +/-10ç for 5±1 seconds
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range
and Humidity range covers non- conducting condition of installed connectors in storage, shipment or during transportation.
Note 3: When FPC is gold plated, the connector contacts must be also gold plated: Specify the (05) plating code.
sMaterials
Part
Insulator
Actuator
Contacts
Metal fitting
Material
LCP
PA
Phosphor bronze
Finish
Color: Black
Color: Dark brown
Tin-lead plated (Note 3)
Tin plated (Lead free)
Remarks
UL94V-0
---------------
---------------
sOrdering information
FH26 - 51S - 0.3 SHW (05)
1
2
3
4
5
1 Series name: FH26
2 No. of contacts: 13, 21, 23, 25, 27, 33, 35, 39,
41, 45, 51, 57, 71
3 Contact pitch: 0.3mm
4 Terminal type: SHW(SMT horizontal mounting)
5 Plating specifications
Blank: Tin-lead plated
(05) : Gold flash plated
2