GS82032AT Datasheet, PDF (14/22 Pages) GSI Technology – 64K x 32 2Mb Synchronous Burst SRAM | |||
|
◁ |
GS82032AT-180/166/150/133/100/66/4/5/6
AC Electrical Characteristics
Parameter
-180
-166
-150
-133
-100
-66
Symbol
Unit
Min Max Min Max Min Max Min Max Min Max Min Max
Clock Cycle Time
tKC 5.5 â 6 â 6.6 â 7.5 â 10 â 12.5 â ns
Clock to Output Valid
Pipeline Clock to Output Invalid
tKQ
tKQX
â 3.2 â 3.5 â 3.8 â 4 â 5 â 6 ns
1.5 â 1.5 â 1.5 â 1.5 â 1.5 â 1.5 â ns
Clock to Output in Low-Z tLZ1 1.5 â 1.5 â 1.5 â 1.5 â 1.5 â 1.5 â ns
Clock Cycle Time
tKC 9.1 â 10 â 10.5 â 12 â 15 â 20 â ns
Flow
Clock to Output Valid
tKQ
â 8 â 8.5 â 9 â 10 â 12 â 18 ns
Through Clock to Output Invalid tKQX 3 â 3 â 3 â 3 â 3 â 3 â ns
Clock to Output in Low-Z tLZ1
3 â 3 â 3 â 3 â 3 â 3 â ns
Clock HIGH Time
tKH 1.3 â 1.3 â 1.3 â 1.3 â 1.3 â 1.3 â ns
Clock LOW Time
tKL
1.5 â 1.5 â 1.5 â 1.5 â 1.5 â 1.5 â ns
Clock to Output in High-Z tHZ1 1.5 3.2 1.5 3.5 1.5 3.8 1.5 4 1.5 5 1.5 6 ns
G to Output Valid
tOE
â 3.2 â 3.5 â 3.8 â 4 â 5 â 6 ns
G to output in Low-Z
tOLZ1
0
â 0 â 0 â 0 â 0 â 0 â ns
G to output in High-Z tOHZ1 â 3.2 â 3.5 â 3.8 â 4 â 5 â 6 ns
Setup time
tS
1.5 â 1.5 â 1.5 â 1.5 â 1.5 â 1.5 â ns
Hold time
tH
0.5 â 0.5 â 0.5 â 0.5 â 0.5 â 0.5 â ns
ZZ setup time
tZZS2
5
â 5 â 5 â 5 â 5 â 5 â ns
ZZ hold time
tZZH2
1
â 1 â 1 â 1 â 1 â 1 â ns
ZZ recovery
tZZR 20 â 20 â 20 â 20 â 20 â 20 â ns
Notes:
1. These parameters are sampled and are not 100% tested.
2. ZZ is an asynchronous signal. However, in order to be recognized on any given clock cycle, ZZ must meet the specified setup and hold
times as specified above.
Rev: 1.12 10/2004
14/22
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
© 2000, GSI Technology
|
▷ |