English
Language : 

MC33999 Datasheet, PDF (5/21 Pages) Motorola, Inc – 16-Output Switch with SPI and PWM Control
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 3. Static Electrical Characteristics
Characteristics noted under conditions 3.1 V ≤ SOPWR ≤ 5.5 V, 5.0 V ≤ VPWR ≤ 18 V, -40°C ≤ TC ≤ 125°C unless otherwise
noted. Typical values noted reflect the approximate parameter means at VPWR = 13 V, TA = 25°C under nominal conditions
unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUT
Supply Voltage Range
Fully Operational
VPWR(FO)
V
5.0
–
27
Supply Current
All Outputs ON, IOUT = 0.3 A
IPWR(ON)
–
mA
4.0
8.0
Sleep State Supply Current at RST ≤ 0.2 SOPWR and / or SOPWR ≤ 0.5 V
IPWR(SS)
–
1.0
10
µA
Overvoltage Shutdown
VOV
27.5
31.5
35
V
Overvoltage Shutdown Hysteresis
VOV (HYS)
0.6
1.4
2.3
V
VPWR Undervoltage Shutdown
VPWR(UV)
–
3.2
4.0
V
SPI Interface Logic Supply Voltage
SOPWR
3.1
–
5.5
V
SPI Interface Logic Supply Current (RST Pin High)
ISOPWR(RSTH)
100
–
500
µA
SPI Interface Logic Supply Current (RST Pin Low)
ISOPWR(RSTL)
-10
–
10
µA
SPI Interface Logic Supply Undervoltage Lockout Threshold
SOPWR (UNVOL)
1.5
2.5
3.0
V
POWER OUTPUT
Drain-to-Source ON Resistance (IOUT = 0.35 A, VPWR = 13 V)
TJ = 125°C
TJ = 25°C
TJ = -40°C
RDS(ON)
Ω
–
0.75
1.1
–
0.55
–
–
0.45
–
Output Self-Limiting Current
Outputs Programmed ON
Output Fault Detect Threshold (10)
Outputs Programmed OFF
Output Off Open Load Detect Current (11)
Outputs Programmed OFF (VPWR = 5.0 V, 13 V, 18 V)
IOUT (LIM)
A
0.9
1.2
2.5
VOUTTH(F)
V
2.5
3.0
3.5
I OCO
µA
25
50
100
Output Clamp Voltage
2.0 mA ≤ IOUT ≤ 200 mA
VCL
V
45
50
55
Output Leakage Current
SOPWR ≤ 2.0 V
IOUT (LKG)
µA
-10
2.0
10
Overtemperature Shutdown (Outputs OFF) (12)
Overtemperature Shutdown Hysteresis (12)
TLIM
155
165
180
°C
TLIM (HYS)
5.0
10
20
°C
Notes
10. Output Fault Detect Thresholds with outputs programmed OFF. Output Fault Detect Thresholds are the same for output open and shorts.
11. Output OFF Open Load Detect Current is the current required to flow through the load for the purpose of detecting the existence of an
open load condition when the specific output is commanded to be OFF.
12. This parameter is guaranteed by design but is not production tested.
Analog Integrated Circuit Device Data
Freescale Semiconductor
33999
5