Pulse-Width Modulator for Motor Control (PWMMC)
12.9.5 PWM Control Register 2
PWM control register 2 (PCTL2) controls the PWM load frequency, the PWM correction method, and the
PWM counter prescaler. For ease of software and to avoid erroneous PWM periods, some of these
register bits are buffered. The PWM generator will not use the prescaler value until the LDOK bit has been
set, and a new PWM cycle is starting. The correction bits are used at the beginning of each PWM cycle
(if the ISENSx bits are configured for software correction). The load frequency bits are not used until the
current load cycle is complete.
See Figure 12-40.
NOTE
The user should initialize this register before enabling the PWM.
Address:
Read:
Write:
Reset:
$0021
Bit 7
6
5
4
3
2
1
0
LDFQ1 LDFQ0
IPOL1 IPOL2 IPOL3 PRSC1
0
0
0
0
0
0
0
= Unimplemented
Bold = Buffered
Figure 12-40. PWM Control Register 2 (PCTL2)
Bit 0
PRSC0
0
LDFQ1 and LDFQ0 — PWM Load Frequency Bits
These buffered read/write bits select the PWM CPU load frequency according to Table 12-8.
NOTE
When reading these bits, the value read is the buffer value (not necessarily
the value the PWM generator is currently using).
The LDFQx bits take effect when the current load cycle is complete
regardless of the state of the load okay bit, LDOK.
Table 12-8. PWM Reload Frequency
Reload Frequency Bits
LDFQ1 and LDFQ0
00
01
10
11
PWM Reload Frequency
Every PWM cycle
Every 2 PWM cycles
Every 4 PWM cycles
Every 8 PWM cycles
NOTE
Reading the LPFQx bit reads the buffered values and not necessarily the
values currently in effect.
IPOL1 — Top/Bottom Correction Bit for PWM Pair 1 (PWMs 1 and 2)
This buffered read/write bit selects which PWM value register is used if top/bottom correction is to be
achieved without current sensing.
1 = Use PWM value register 2.
0 = Use PWM value register 1.
MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1
148