XRT81L27 Datasheet, PDF (26/30 Pages) Exar Corporation – SEVEN CHANNEL E1 LINE INTERFACE UNIT WITH CLOCK RECOVERY
XRT81L27
SEVEN CHANNEL E1 LINE INTERFACE UNIT WITH CLOCK RECOVERY
REV. 1.1.0
áç
FIGURE 13. SCHEMATIC FOR INTERFACING THE RECEIVE SECTIONS OF THE XRT81L27 TO THE LINE FOR 75Ω
(TRANSFORMER-COUPLED) APPLICATIONS
RPOS_n
RTIP_n
RNEG_n
RClk_n
LOS_n
XRT81L27
RRING_n
Line
1: 2
Input
FIGURE 14. SCHEMATIC FOR INTERFACING THE RECEIVE SECTIONS OF THE XRT81L27 TO THE LINE FOR 120Ω
(TRANSFORMER-COUPLED) APPLICATIONS
RPOS_n
RNEG_n
RTIP_n
RClk_n
LOS_n
RRing_n
XRT81L27
1:2
Line
Input
The Transformer used should be 1:2 step up for
Transmit direction and 2:1 step down for the Receive
direction. The following transformers are recommend-
ed: Pulse PE-65681, Pulse T1090, and HALO TG08-
1505N1.