English
Language : 

HR10A-TC-02 Datasheet, PDF (18/20 Pages) List of Unclassifed Manufacturers – Push-Pull Connectors
HR10 Series●Push-Pull Connectors
■Connection work procedure(plug side)
This applies also to the jack side connection work.
No special connection work procedure is given here for the receptacle side because no special procedure is
necessary.
P shell unit
Plug body
Clamp washer
Bifurcated part
Tightener Cable
About 2
C
P shell unit
Clamp
Face A
Face B
Spanner jaw distance
Plug body
Spanner jaw distance
Cord bushing
Cable
A
About 2 for solder type
2
0
-0.5
for
crimp
type
2 or more
D
Boss
Set screw
Table 2 spanner jaw distance
Size HR10 HR10A
Size 7
8
7.5
Size 10
11
9.5
Size 13
––
13
Table 3 cable end processing dimensions
Size
Dimension C Dimension D for HR10A
for HR10 Solder type Crimp type
Size 7 5.5 or less
10
15-20
Size 10 7 or less
16
15-20
Size 13
––
26
26
Table 1
Size
Size 7
Size 10
Size 13
Tightening force
1.5N∙m(15kg∙cm)
2N∙m(20kg∙cm)
2N∙m(20kg∙cm)
HR10 TYPE
HR10A TYPE
1 Use cables with a nominal sectional area of 0.129 mm2 (AWG#26) at the finish outside diameters applicable for each size.
After processing the cable ends according to the dimensions in the above drawings, fit the parts to the cable as shown in the drawings.
2 Fit the parts to the cable in the following order: tightener, clamp Fit the parts to the cable in the following order: cord bushing and
washer, and plug body.
plug body.
(solder type)
3
Insert the P shell unit into the assembly tool stand and solder it.
(crimp type)
After crimping the appropriate crimp terminal to the cable core, insert the crimp terminal into the terminal hole in the P shell unit.
Assemble the connector in the following steps.
1.Screw the plug body into the thread in the P shell unit with the 1.Fix by caulking the clamp accompanying the cable with the cable
tightening force shown in Table 1 using a torque wrench with a
crimping tool(HR10A-TC-02)
fixed torque.
2.Screw the plug body into the thread in the P shell until with a
Before tightening the plug body,slacken part C so that no load is
tightening force shown in Table 1 using a torque wrench with a
4
applied to the soldered wires.
fixed torque. Before tightening the plug body, slacken the part D so
2.Apply the clamp washer to the bifurcated part of the plug body,
that no load is applied to the soldered wires.
and then tighten the tightener until surface B touches the plug 3.Tighten the set screw so that the tip of the screw presses one of
body surface A.
the two bosses on the clamp.
Fix the set screw with a tightening torque of 0.3N(3kg∙cm)
4.Attach the cord bushing to the plug body.
5 This completes the work.
For any question on using the plugs, contact our sales or engineering department.
Remarks : Loctite 242, Henkel Japan or equivalent is recommend to prevent the male thread section of the P shell unit and the set screw
for loosing.
196