■Cable connecting methods
1.Cable end treatment
Fig.1
11±0.5
HR10 Series●Push-Pull Connectors
HR10B-2.5CP
HR10B-2.5CJ
3.Crimping cable outer conductor
Fig.3
(HR10B-2.5CP)
A
1.4±0.2
(2.5) 3.7±0.2
Slit cable outer jaket
2 pieces (180° reverse side)
1.Dimensions for cable end treatment are shown in
Fig 1.
2.Termination is described below.
(1).Strip cable outer jacket as indicated.
(2).Slit outer jacket on both sides per Fig.1.
(3).Fold back outer cover.
(4).Remove insulator from cable.
2.Soldering male pin to cable center
conductor.
Fig.2
Malu pin or Female pin
Soldering
Should fix flush
Contact fixing jig
such as vise
1.Solder male pin to cable center conductor as
indicated in Fig.2.
(1).Pre-solder the solder pot of pin with Ø0.5mm
string solder.
(2).Male pin should fit flush against the cable
insulator as shown.
(3).Remove any excess solder from the pin with a
knife.This surface must be smooth.
(4).A properly soldered terminal will yield 500gf
when stretched.
Clamp metal
Connector
Remove excess insulator
material (remaining after
clamping is complated)
with a knife or aimilarobject.
Table 1 dimenshion A
2.5CP
2.5CJ
1.5±0.2mm
0
+0.3
0
mm
1.Insert cable prepared per PROCESS 2 into the
connector.The cable should be inserted until it
comes to a full stop.This may be verified by
checking the dimension from the side of the
connector to the top of the contact(as indicated in
Fig 3). This dimension should be A.
2.Crimp this installed metal clamp with tool HR10-
TC-01 per Fig.3 and remove excess insulation with
a knife.
It is possible to pull back the contact.
Hold cable when crimping metal clamp and keep
the dimension to show in Fig 3. after crimping metal
clamp.
189