K3NR Datasheet, PDF (21/28 Pages) List of Unclassifed Manufacturers – High-speed, Intelligent Interface Modules
Protect Mode
Changing Set Values
By pressing the Shift Key while a parameter is displayed, the set value can be
changed (setting status). The PROG status indicator will flash. Change the set
value as required, and press the Mode Key to register the setting and move to
the next parameter.
func
Setting Status
f1
Change the set value
using the Up Key and
the Shift Key .
PROG flashes.
If there is no key operation for
Next parameter 5 seconds, the setting is
registered and the parameter
is displayed again.
Prescaling menu
1s
Prescale value
−
bank (See note 1.)
(See note 4.) No key operation for 5 s
Input A prescale
value mantissa
−
−
No key operation for 5 s
(See note 4.)
Input A prescale
value exponent
−
−
No key operation for 5 s
(See note 4.)
Input B prescale value
mantissa (See note 2.)
−
−
No key operation for 5 s
(See note 4.)
Input B prescale value
exponent (See note 2.)
−
−
No key operation for 5 s
Decimal point
−
No key operation for 5 s
• In the Setting Mode, measurement stops and all outputs turn
OFF.
• Depending on the output type of the model used, some param-
eters (indicated in
) are not displayed (and hence can-
not be set).
• If the operating mode is changed, the prescale values and lin-
ear output range parameters will be reset to their initial values.
Set the operating mode first.
Note 1: Set a number in the range 2 to 4 to set more than one prescale value
(i.e., to display measurements in more than one unit).
2: These parameters will be displayed if F2, F3, F4, or F5 (i.e., operating
mode 2, 3, 4, or 5) is set.
3: This parameter is displayed if F6 (i.e., operating mode 6) is set. If a
parameter other than 5cal is set, the prescaling menu ( p5cl) will not be
displayed.
4. A number in the range 1 to 4 will be displayed.
Setup menu
1s
Operating mode
Input A
sensor type
Input B sensor
type (See note 2.)
Input A auto-zero
time mantissa
Input A auto-zero
time exponent
Input B auto-zero
time mantissa
(See note 2.)
Input B auto-zero
time exponent
(See note 2.)
Time unit
(See note 3.)
Communications
unit number
Baud rate
Word bit length
Stop bits
Parity bits
−
No key operation for 5 s
No key operation for 5 s
No key operation for 5 s
−
No key operation for 5 s
−
No key operation for 5 s
−
No key operation for 5 s
−
No key operation for 5 s
No key operation for 5 s
−
No key operation for 5 s
1200/2400/4800/
9600 /19200/38400bps
No key operation for 5 s
7 /8bit
No key operation for 5 s
1/ 2 bit
No key operation for 5 s
/
/
Settings displayed in reverse colors are defaults.
Frequency/Rate Meter K3NR K-149