SI5010 Datasheet, PDF (5/16 Pages) List of Unclassifed Manufacturers – OC-12/3, STM-4/1 SONET/SDH CLOCK AND DATA RECOVERY IC | |||
|
◁ |
Si5010
Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter
Symbol
Test Condition
Min1 Typ Max1 Unit
Ambient Temperature
TA
Si5010 Supply Voltage2
VDD
â40
25
85
°C
2.375 2.5 2.625
V
Notes:
1. All minimum and maximum specifications are guaranteed and apply across the recommended operating
conditions. Typical values apply at nominal supply voltages and an operating temperature of 25°C unless
otherwise stated.
2. The Si5010 specifications are guaranteed when using the recommended application circuit (including
component tolerance) of Figure 5 on page 8.
V
SIGNAL +
Differential VICM, VOCM
VIS
I/Os SIGNAL â
(SIGNAL +) â (SIGNAL â)
Differential
Voltage Swing
V ID ,V O D
Differential Peak-to-Peak Voltage
t
Figure 2. Differential Voltage Measurement
tC-D
DOUT
CLKOUT
Figure 3. Clock to Data Timing
DOUT,
CLKOUT
80%
20%
tF
tR
Figure 4. DOUT and CLKOUT Rise/Fall Times
Preliminary Rev. 0.31
5
|
▷ |