English
Language : 

SI5010 Datasheet, PDF (5/16 Pages) List of Unclassifed Manufacturers – OC-12/3, STM-4/1 SONET/SDH CLOCK AND DATA RECOVERY IC
Si5010
Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter
Symbol
Test Condition
Min1 Typ Max1 Unit
Ambient Temperature
TA
Si5010 Supply Voltage2
VDD
–40
25
85
°C
2.375 2.5 2.625
V
Notes:
1. All minimum and maximum specifications are guaranteed and apply across the recommended operating
conditions. Typical values apply at nominal supply voltages and an operating temperature of 25°C unless
otherwise stated.
2. The Si5010 specifications are guaranteed when using the recommended application circuit (including
component tolerance) of Figure 5 on page 8.
V
SIGNAL +
Differential VICM, VOCM
VIS
I/Os SIGNAL –
(SIGNAL +) – (SIGNAL –)
Differential
Voltage Swing
V ID ,V O D
Differential Peak-to-Peak Voltage
t
Figure 2. Differential Voltage Measurement
tC-D
DOUT
CLKOUT
Figure 3. Clock to Data Timing
DOUT,
CLKOUT
80%
20%
tF
tR
Figure 4. DOUT and CLKOUT Rise/Fall Times
Preliminary Rev. 0.31
5