English
Language : 

OXFW911 Datasheet, PDF (5/32 Pages) List of Unclassifed Manufacturers – IEEE1394 to ATA/ATAPI Native Bridge
OXFORD SEMICONDUCTOR LTD.
OXFW911
3 PIN DESCRIPTIONS
1394 PHY-LINK interface
104, 105, 108, 109, 110, 111, 114,
115
116,117
119
121
102
103
ARM external interface
2, 3, 4, 5, 6, 9, 10, 11, 12, 13, 16,
17, 18, 19, 20, 24
35, 36, 37, 38, 41, 42, 43, 44, 45,
46, 49, 50, 51, 52, 53, 54, 60
123, 124, 27, 33
Dir1
I/O
I/O
I
O
IU
O
T_I/O
T_O
T_O
Name
PD[7:0]
CTL[1:0]
PHYCLK
LREQ
LINKON
LPS
D[15:0]
A[16:0]
CS#[3:0]
28
T_O OE#
34
61
IDE interface
86, 82, 80, 78, 74, 72, 70, 66, 65,
69, 71, 73, 77, 79, 81, 85
99, 97, 98
101, 100
T_O WE#
T_IU INT#
T_I/O ID[15:0]
T_O IA[2:0]
T_O ICS#[1:0]
63
T_O IDE_OE#
64
89
90
91
92
95
62
EEPROM interface
125
126
127
58
Miscellaneous Pins
56
128
22, 32, 31
57
T_O IRESET
T_I DMARQ
T_O DIOW#
T_O DIOR#
T_O IORDY
T_O DMACK#
T_I INTRQ
O GPO1
O GPO2
O GPO3
T_IU GPI
IU RESET#
T_O CKOUT
I TEST_SEL,
TEST[1:0]
IU UIF
Power and ground2
15, 8, 40, 48, 59, 76, 94, 107, 113
30, 21, 23, 68, 84, 88, 120
VDD AC VDD
VDD DC VDD
Data Sheet Rev 1.1
Description
Phy-Link Data Bus
Phy-Link Control Bus
49.152 MHz clock sourced by PHY
Link Request
Requests link to power up when in a low power mode
Indicates to phy that link is powered and ready
ARM external data bus
ARM external address bus
ARM external chip selects. CS0# is always used for program
ROM.
ARM external output enable. Active when reading data from
external devices including program ROM
Write Enable. Active when writing to external devices
External ARM interrupt
IDE data bus
IDE address bus
IDE chip select. Used to select the Command Block or
Control Block registers.
IDE output enable. Only used when external buffering is
required to drive IDE data bus
IDE interface reset
IDE interface write strobe
IDE interface read strobe
General Purpose Output 1
General Purpose Output 2
General Purpose Output 3
General Purpose Input
Global reset for the OXFW911. Active Low.
Clock output. 49.152 MHz clock output.
‘100’ = NORMAL OPERATION. Other settings are for
foundry test purposes only.
Leave unconnected to use internal Flash, tie low to use only
external device
Supplies power to output buffers in switching (AC) state
Power supply. Supplies power to core logic, input buffers
and output buffers in steady state
Page 5