English
Language : 

LM3S316 Datasheet, PDF (367/421 Pages) List of Unclassifed Manufacturers – Microcontroller
LM3S316 Data Sheet
Register 5: PWM Output Fault (PWMFAULT), offset 0x010
This register controls the behavior of the PWM outputs in the presence of fault conditions. Both the
fault input and debug events are considered fault conditions. On a fault condition, each PWM
signal can either be passed through unmodified or driven Low. For outputs that are configured for
pass-through, the debug event handling on the corresponding PWM generator also determines if
the PWM signal continues to be generated.
Fault condition control happens before the output inverter, so PWM signals driven Low on fault are
inverted if the channel is configured for inversion (therefore, the pin is driven High on a fault
condition).
PWM Output Fault (PWMFAULT)
Offset 0x010
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
Fault3 Fault2 Fault1 Fault0
Type
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:4
3
2
1
0
Name
reserved
Fault3
Fault2
Fault1
Fault0
Type
RO
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
Description
Reserved bits return an indeterminate value, and should
never be changed.
When set, the PWM3 output signal is driven Low on a fault
condition.
When set, the PWM2 output signal is driven Low on a fault
condition.
When set, the PWM1 output signal is driven Low on a fault
condition.
When set, the PWM0 output signal is driven Low on a fault
condition.
April 27, 2007
367
Preliminary