5.2.5.5 Error and Status Bits
E981.07
The conditions for setting and clearing of status bits in Sensor Data Request message are defined in the table
below.
Bit Description
OE Over-current
Error
ND No Data
CNC Conditions
Not Correct
HE Hardware
Error
ME Manchester
Error
Setting Condition
Satellite channel short to V+
condition
• no sensor data arrived since
enabling of the channel
• second attempt to read
sensor data from one logical
channel, although no new
sensor data has been
received intermediately
• Request for undefined
channel
• request for a channel not yet
turned on
• Satellite channel short to
GND condition
• Satellite average Iq too high
• Channel over-temperature
• REXT out of range
• CLK malfunction
• VSYNC too low
• VBUS too low
Improper manchester data:
• Invalid bit count
• Invalid bit timing
Clearing Condition
Channel Behaviour
• External reset
Channel is
• Internal reset
deactivated
• LINE_ENABLE command
with LEx=0 (OFF) for the
affected channel
Cleared after a new satellite None
data is received
• External reset
• Internal reset
• requesting an activated
channel
None
• External reset
Channel is
• Internal reset
deactivated
• LINE_ENABLE command
with LEx=0 (OFF) for the
affected channel
• External reset
• Internal reset
• Cleared when read
None
DE Data
Error
• Satellite Data Parity Error
• External reset
• Internal reset
• Cleared when read
None
The next tables summarises the error handling and the error priority.