E981.07 Datasheet, PDF (30/46 Pages) ELMOS Semiconductor AG – Two independent operating channels
Two Channel Sensor Interface PSI5
ADVANCE PRODUCT INFORMATION JUL 26, 2011
5.2.5.4 Logical Channel Assignment
E981.07
The Logical Channel field is used to address one of the six possible satellites connected to the two physical
channels of the 981.07. Each physical channel can support up to three satellites. Each of these three satellites
is assigned to a separate time slot on the bus. Each time slot has a appropriate sensor data register (A, B, C).
The 981.07 response to requests for undefined physical channels with an error message with the CNC bit is set
(CNC=1). This illustrated in the table below.
Logical Channel
LC[3:0]
0000
0001
0010
0011
0100
0101
0110
other
Physical
Channel
1
1
1
undefined
2
2
2
undefined
Time Slot
1
2
3
-
1
2
3
-
Sensor Data
Register
A1
B1
C1
-
A2
B2
C2
-
ELMOS Semiconductor AG
Data Sheet 30 / 45
QM-No.: 25DS0050E.00
This document contains information on a new product. ELMOS Semiconductor AG reserves the right to change specifications and information herein without notice.